Technical information Crab range

285 FALSEWORK - TECHNICAL INFORMATION - 2023 FALSEWORK 8 •Move the four 0.30 m Panaciers while moving backwards inside the tower. •Mandatory wind bracing of the central side with one ledger and one diagonal brace. •Fit and adjust the telescopic standards, the screw-jack heads and the fork heads. •Fit the adjustable ledgers and diagonal braces on the screw-jack heads of the first section. 10 •Move the PANATRAP. •From the lower level, move the 2 remaining PANACIERs and fix the access ladder under the Panatrap. •Raise the upper level and continue assembling repeating steps no. 3 to 9 as many times as necessary. 9 11 •Mandatory wind bracing of the central side with one ledger and one diagonal brace. •Finish the terminations and adjust the last 2 bases of the fork heads. •Remove the 2 assembly PANACIERs. •Inspect the tower and draft the acceptance report. Dismantle in the reverse order of assembly. DISMANTLING The central side must be wind-braced with diagonal braces and ledgers on all levels. Add two 1.50 m x 0.30 m PANACIERs for assembly and dismantling. Possibility of using only PANATRAPs without a ladder in place of the PANACIERs. VARIANT See the assembly recommendations presented at the beginning of this technical information. PPE attachment points: refer to the PPE chapter.