137 MULTICRAB - TECHNICAL INFORMATION - 2023 MULTICRAB TECHNICAL DATA CALCULATION FOR FAÇADES 24 m tall F (daN) = qp x Sa x Ct x ϕE Non-covered Net Canvas cover Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Region 1 61 51 80 67 413 349 Region 2 72 61 95 80 490 414 Region 3 85 72 111 94 573 486 Region 4 98 83 129 109 666 564 F (daN) = qp x Sa x Ct x ϕE Non-covered Net Canvas cover Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Region 1 76 64 100 84 516 436 Region 2 90 76 119 100 613 518 Region 3 106 90 139 118 716 608 Region 4 122 104 161 136 832 705 F (daN) = qp x Sa x Ct x ϕE Non-covered Net Canvas cover Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Cprob = 1 Cprob = 0.92 Region 1 91 77 120 101 619 523 Region 2 108 91 143 120 736 622 Region 3 127 108 167 142 859 730 Region 4 146 125 193 163 998 846 Non-weighted maximum loads on the upright bearing the greatest load Maximum non-weighted forces in the anchor point subject to the most stress 2.00 m ledger Non-covered, net or canvas cover: anchor points in a staggered arrangement every 4.00 m or 8.00 m. F (daN) 0.70 m wide 1.00 m wide Without 0.30 m Without 0.30 m cantilever Cantilever cantilever Cantilever Class as per class 6 class 5 class 6 class 5 NF EN12810/11 600 daN/m2 450 daN/m2 600 daN/m2 450 daN/m2 PP (daN) 585 551 670 638 Q (daN) 630 878 900 1,080 F = PP + Q 1,215 1,429 1,570 1,718 PP = Scaffolding own weight Q = Working load * with 1.00 m reinforced ledger * with 1.00 m reinforced ledger Non-covered: anchor points in a staggered arrangement every 8.00 m Net or canvas cover: anchor points in a staggered arrangement every 4.00 m Non-covered: anchor points in a staggered arrangement every 8.00 m Net or canvas cover: anchor points in a staggered arrangement every 4.00 m 2.50 m ledger 3.00 m ledger F (daN) 0.70 m wide 1.00 m wide Without 0.30 m Without 0.30 m cantilever Cantilever cantilever Cantilever Class as per class 5 class 4 class 4 class 3 NF EN12810/11 450 daN/m 300 daN/m2 300 daN/m2 200 daN/m2 PP (daN) 758* 740 883 865 Q (daN) 709* 878 675 720 F = PP + Q 1,467 1,618 1,558 1,585 Class as per class 5 class 4 class 4/5* class 4 NF EN12810/11 450 daN/m2 300 daN/m2 300/450 daN/m2 300 daN/m2 PP (daN) 758* 740 883/883* 865 Q (daN) 709* 878 675/1,013* 1,080 F = PP + Q 1,467 1,618 1,558/1896* 1,945 F (daN) 0.70 m wide 1.00 m wide Without 0.30 m Without 0.30 m cantilever Cantilever cantilever Cantilever Class as per class 6 class 4 class 5 class 4 NF EN12810/11 600 daN/m2 300 daN/m2 450 daN/m2 300 daN/m2 PP (daN) 672 645 779 751 Q (daN) 788 732 844 900 F = PP + Q 1,460 1,377 1,623 1,651 Class as per class 6 class 4 class 5/6* class 4 NF EN12810/11 600 daN/m2 300 daN/m2 450/600 daN/m2 300 daN/m2 PP (daN) 672 645 779 751 Q (daN) 788 732 844/1,125* 900 F = PP + Q 1,460 1,377 1,623/1904* 1,651 1 2 1 1 1 2 2 2 Non-covered, net or canvas cover: anchor points in a staggered arrangement every 4.00 m or 8.00 m. Non-covered, net or canvas cover: anchor points in a staggered arrangement every 4.00 m or 8.00 m.
RkJQdWJsaXNoZXIy OTQ2MzM=